32 / F32 Surface Vertical Rod Exit Devices (SVR)

32 / F32 Surface Vertical Rod Exit Devices (SVR)

32 / F32 Surface Vertical Rod Exit Devices (SVR)

Applications

Offices, schools, banks, assisted living facilities and other institutions or commercial buildings.

Doors & Preparations

  • For all types of single and double doors.
  • For new or retrofit installation into other manufacturers’ devices.
  • For doors 1-3/4″ to 2-1/4″ (45mm to 57mm) thick, up to 4′ (1219mm) wide opening and up to 10′ (3048mm) high; for thicker doors, consult factory.
  • Furnished standard for 1-3/4″ (45mm) thick, 3′ (915mm) wide opening and 7′ (2134mm) high doors.
  • For maximum door opening applications and listings.

Specifications

Certification/Compliance• Panic devices UL/cUL listed for UL305 and ANSI/BHMA A156.3 Grade 1 Panic Hardware.
• UL/cUL Fire rated for 3-hour Fire Exit Hardware, conforms to UL10C and UBC7-2. Also complies with NFPA 80 Fire doors and windows.
• Exit devices, levers, trims and pulls comply with American Disability Act (ADA) and NFPA 101 life safety code.
Center Case• Heavy wrought steel assembly with top and bottom rod adjustors.
Vertical Rods• 1/2" (12.7mm) square tubing, standard rods accommodate 7' (2134mm) door.
• Top rod length is 38-3/16" (970mm), bottom rod length is 34-1/16" (865mm) standard.
• Top rod length 50-3/16" (1275mm) is available for 8' (2438mm) door.
• Extension rod available 24" (609mm) for doors ranging between 8' (2438mm) and 10' (3048mm) high. Specify when ordering.
Top Latchbolt• Alloy steel, Pullman type deadlocking, 5/8" (16mm) throw.
Bottom Latchbolt• Alloy steel, Pullman type deadlocking, independent action 5/8" (16mm) throw.
• Round slide bolt optional.
Top &
Bottom Latch Case
• 4-1/2" x 2-1/8" x 1-1/2" (114mm x 54mm x 38mm).
Door Undercut1/4” (6mm)
StrikesPanic:
Top: P/N. 106Z (roller type)
Bottom: P/N. 227

Fire:
Top: P/N. 108 (roller type)
Bottom: P/N. 227F
Dogging• NOT available on Fire Exit Hardware.
• Dogging options available for LD, CD.
• Flat/Hex key dogging standard.
Fasteners• Machine screws and wood screws are furnished standard.
Sex Bolts (SNB)• Required when used with wood, composite or non-reinforced hollow metal doors.
For exit only device, specify 6-1024 SNB (No. 10-24) and 4-4120 SNB (No. 1/4-20).
For device with trim, specify 2-1024 SNB (No. 10-24) and 4-4120 SNB (No. 1/4-20).
Electric FunctionsCan be interfaced with building security systems:
• AL Alarm Exit
• LM Latchbolt Monitoring
• RX Request to Exit
Device Centerline from Finished Floor• 39-5/8" (1006mm).
Fire Bolt Less Bottom Rod• Available for door openings up to 8' (2438mm) wide × 10' (3048mm) high. Specify suffix "LBR".
• Fire bolt is heat activated - used in Less Bottom Rod (LBR) option for fire exit devices.
Handing• Device & trim non-handed.
Cylinders• NOT furnished standard, specify when required.
Trim• The device and trim are sold separately, easy to mix and match.