Applications
Offices, schools, banks, assisted living facilities and other institutions or commercial buildings.
Doors & Preparations
- For all types of single and double doors with a mullion. For mullions.
- Available for 1 3/4″ to 2 1/4″ thick, up to 4′ wide opening.
- For thicker doors, consult factory.
- For new or retrofit installation into other manufacturers’ devices.
- Furnished standard for 1 3/4″ thick, 3′ wide opening.
- For maximum door opening applications and listings for Fire Exit Devices.
Specifications
Stile | • Minimum width 2" (51mm). |
Certification/Compliance | • Panic devices UL/cUL listed for UL305 and ANSI/BHMA A156.3 Grade 1 Panic Hardware. • UL/cUL Fire rated for 3-hour Fire Exit Hardware, conforms to UL10C and UBC7-2. Also complies with NFPA 80 Fire doors and windows. • Exit devices, levers, trims and pulls comply with American Disability Act (ADA) and NFPA 101 life safety code. |
Center Case | • Universal center case, heavy wrought steel and sintered metal parts. • Device functions are determined by adaptation with type of trim. |
Strikes | Panic: P/N. 103/106 (roller type) Fire: P/N. 108 (roller type) |
Dogging | • NOT available on Fire Exit Hardware. • Dogging options available for LD, CD, ED (ELR). • Flat/Hex key dogging standard. |
Fasteners | • Machine screws and wood screws are furnished standard. |
Sex Bolts (SNB) | • Required when used with wood, composite or non-reinforced hollow metal doors. For Exit Only device, specify 2-1024 SNB (No. 10-24) and 2-4120 SNB (No. 1/4-20). For device with trim, specify 2-1024 SNB (No. 10-24). |
Electric Functions | Can be interfaced with building security systems: • AL Alarm Exit • DE Delayed Egress Device • ELR Electric Latch Retraction • LM Latch Bolt Monitoring • RX Request to Exit • SS Signal Switch |
Device Centerline from Finished Floor | • 39-5/8” (1006mm) |
LatchBolt | • Stainless Steel, deadlocking, 3/4" (19mm) throw. |
Handing | • 500 Series Trim field reversible. • Device non-handed. • Specify handing for 400 Series trim when ordering. |
Cylinders | • NOT furnished standard, specify when required. |
Trim | • The device and trim are sold separately, easy to mix and match. |